Various Individual Components


New Pulse Counter/Interval Timer
  • Discriminate pulse events from a noise background, for
  • pulses of amplitude 10 mV to > 1 Volt
  • Correctly count 'events per unit time', with 0.1, 1.0, or
  • 10-second counting intervals
  • Alternatively, measure the time interval between a pulse and
  • its successor pulse, to 1- µs resolution
  • Write date files of unlimited length of successive counts per unit
  • time, or intervals between successive counts.

Photodiode Photodetectors

Large Area Photodetector with Base

  • Developed for Modern Interferometry
  • Silicon Pin photodiode OSI Optoelectronics model # PIN 10D1
  • Spectral range: 400 - 1,000 nm
  • Active area: 100 mm2, 11.3 mm diameter
  • Responsivity at 800 nm: 0.6 A/W
  • Gain: 2 x 203 to 12 x 106 V/A (10 steps; 1, 2, 5, 10 sequence)
  • Bandwidth 200 kHz to 5 kHz (gain dependent)
  • Requires Power Supply: ±5 to ± 15 V

Small Area Photodetector with Base
  • Developed for Diode Laser Spectroscopy and Optical Pumping
  • Silicon Pin photodiode OSI Optoelectronics model # PDB-C108
  • Spectral Range 400 - 1,000 nm
  • Active area 31 mm2, 6.2 mm diameter
  • Responsivity at 800 nm: 0.6 A/W
  • Gain: 333 - 107 V/A (10 steps; 1, 3.3, 10 sequence)
  • Bandwidth 500 kHz - 5kHz (gain dependent)
  • < li>Requires power supply:±5 to ± 15 V

High-Stability Proprietary Flexure Mirror Mounts with Base and Extra Mirror
  • Developed for Modern Interferometry
  • Allow only one degree of freedom
  • Order any combination of Horizontal and Vertical tilt
  • Mirror can be set at 90, 45, or 22.5 degrees to breadboard dimension

High-Stability Proprietary Flexure Translation Stage
  • Proprietary High-Stability Flexure Translation Stage Developed for Modern Interferometry
  • Allows ±1 mm of pure translation preserving full fringe contrast
  • Enables counting of hundreds or thousands of fringes
  • Can be used with standard or flexure mirror mounts
  • Includes push-rod and v-block kit
  • Adaptable to standard or differential micrometer for control or calibration

Magnetostriction Kit
  • Custom solenoid
  • Includes three samples: Copper, Iron, Nickel
  • Requires Flexure Translation Kit
  • (shown with proprietary mirror mount)

Differential Pressure Transducer
  • Developed for Modern Interferometry
  • Honeywell model # 26PCCFA6D sensor
  • Maximum pressure difference: ± 1 atm.
  • Output: ± 10V = ± 1 atmosphere
  • Requires power supply ±12 - ± 15 Volts


Grating Stabilized Diode Laser Head with Controller and three tested diodes
  • Developed for Diode Laser Spectroscopy
  • Includes 3 tested diodes
  • Temperature Controlled
  • Removable Grating
  • Sanyo DL-7140-201S infrared diode laser
  • Maximum Power: 70 mW
  • Wavelength range: 15 nm coarse, 10 GHz fine
  • Temperature Range: 0 - 60 C
  • Current; 0 - 100 mA, Noise ‹ 0.5 µA rms
  • Piezo modulation: 0 - 100 V
  • Ramp Gen: 1 mHz - 10 kHz, 0 - 10 Vp-p

Rubidium RF Discharge Lamp
  • Developed for Optical Pumping
  • Mounted in 120° C temperature regulated oven
  • Rb Bulb 9 mm diameter
  • Natural isotopic concentration
  • 3 Torr Xenon buffer
  • RF Oscillator 75 - 90 MHz
  • Optical power at 795 nm › 1mW/steradian
  • Power Requirements: 28 V @ 0.5 A, user supplied

Mounted Interference Filter for Optical Pumping
  • Developed for Optical Pumping
  • Intor model #805/35/75-8U
  • Center wave length: 805 nm
  • Spectral Width: 35 nm
  • Peak transmission: 75%
  • Transmission: at 795 nm › 75%; at 780 nm ‹ 5%
  • Diameter: 2 inches
  • Available with .5" stainless steel or .25" Delrin post